logo
  • Home
  • Company
    • Profile & History
    • Man Power
    • Fairs & Exhibitions
    • Project References
    • Office & Warehouse
  • Product :
  • DSE
    • Overview
    • Manual Start / Auto Start
    • Auto Transfer Switch - ATS
    • Auto Mains Failure - AMF
    • Load Share / Synchronising
    • Remote Communication
    • Battery Charger - Power Supply
    • DSE Power
    • DSE Control
    • DSE Marine
    • DSE Extra
    • DSE Net
    • Others Product
  • Moeller
    • Overview
    • Control Indication
      • RMQ Titan, RMQ 16
      • SL Signal Tower
      • Electronic position switch
      • Mechanical position switches
      • T Rotary Switches & P Switch disconnector
    • Control & Visualisation
      • Timing relays ETR
      • Safety Relay ESR
      • Measuring & Monitoring Relay –EMR
      • Easy Control Relay
    • Switching Protecting and Driving Motors
      • DIL contactors, 3-pole
      • DIL contactors, 4-pole
      • DIL E mini contactor relay
      • DIL A contactor relay
      • Motor Protective Relay
      • Motor-protective circuit-breakers
      • Motor starters MSC
    • Power Distribution
      • MCB
      • MCCB
      • ACB
  • ABB
    • Overview
    • Power Capacitors
    • Power Factor Regulator
    • Harmonic Filter Reactor
  • Services
    • Power Quality Evaluation
      • Power Analyzer
    • Earth Grounding Measuring
      • Earth Ground Tester
  • Contact Us
Home
Wednesday, 20 April 2016 03:29

ERN 11206 / ERN 11214 Featured

Written by  Administrator
  • font size decrease font size decrease font size increase font size increase font size
  • Print
  • E-mail
Rate this item
  • 1
  • 2
  • 3
  • 4
  • 5
(0 votes)
ERN 11206 / ERN 11214

 

 

 

 

 

 

 

 

 

 

 

 

 

SMART SERIES

ERN 11206 / ERN 11214

 

EXCELLENT POWER FACTOR CONTROL, ANALYSIS AND CONTROL OF HARMONIC, SUITABLE FOR LV AND MV VOLTAGE SYSTEMS.

  • Digital microprocessor controller designed for automatic power factor correction systems
  • Relay outputs to connect or disconnect the capacitor banks
  • Selectivity of capacitors – Using intelligent way (work hours and the required reactive power)
    • During the control ERN 11214 continually checks the relay compensation section, when in detects a capacity loss or change in value, it temporarily disables the section under relevant setting.
    • The temporarily disable section is anyway tested st regular intervals and when possible enable again control.
  • Reliable power factor control even in presence of high current and/or voltage harmonics content.
  • Current and voltage harmonic analysis up to 19 order.
  • In case an abnormal situation in the system (calculated from THD and CHL measurements) the controller disconnects all compensation sections for preventing their damage.
  • Display 4 digits 7 segment LED.
  • Measure and display the following parameters. Information shown on the numeric display are divided into 3 main data group :
    • Instantaneous power system values measured such as power factor, active power, reactive power, apparent power, current, voltage, THDI, THDV and capacitors CHL, frequency, power.
    • Controller parameters target power factor, control period, reconnection delay time, total recorded connected times, numbers of connections of each compensation bank, etc.
    • Test and error messages.
  • No-voltage release protection.
  • Capacitor overload and panel overheating protection.
  • Suitable for co-generation systems (4 quadrant operation)
  • 3 way parameter set-up automatic, manual, PC.
  • RS232 or RS485 communication interface for st-up and automatic testing with Personal Computer.
  • Adjustable reconnections time delay.
  • Specila Voltage Optional
    • Voltage measurement input and second metering rate input – suitable for MV capacitors banks.

 

POWER FACTOR AUTOMATIC CONTROLLERS ERN11206/ERN11214

 

SMART SERIES ERN-11206/ERN-11214-TECHNICAL DATA


Last modified on Wednesday, 20 April 2016 18:50
Read 18815 times
Product Category : Regulator
Social sharing
  • Add to Google Buzz
  • Add to Facebook
  • Add to Delicious
  • Digg this
  • Add to Reddit
  • Add to StumbleUpon
  • Add to MySpace
  • Add to Technorati
Administrator

Administrator

Latest from Administrator

  • SecoRMU
  • 12kV/17.5kV/24kV
  • CSC GE-RT3
  • RCM-AP-3
  • Residual Current Circuit-Breakers
back to top
dse
kmniaga Jean Muller
ANV erico
  • Home
  • Company
  • Product :
  • DSE
  • Moeller
  • ABB
  • Services
  • Contact Us

Contact Us

Pergudangan Daan Mogot Arcadia
Jl. Daan Mogot Km .21
Blok : G1 No 10
Batu Ceper -  tangerang 15122

Tel  : +62-21-55 303 88
Fax : +62-21-55 3-3 77

Lindeteves Trade center
Lt. UG, Blok : B17 No. 1
Jl. Hayam Wuruk No. 127
Jakarta 111180

Tel  : +62-21-622 00397
Fax : +62-21-622 00397
Komplek Ruko Rungkut Mega Raya
Jl. Raya Rungkut, No.5, Blok D31
Surabaya

Tel.: +62-31- 879 4331
Fax: +62-31- 897 4325

Copyright © 2011 KM Niaga. All Rights Reserved. Designed and developed by Djavaweb